Breakdowns
COMBUSTION CHAMBER
CABINET ASSEMBLY
BURNER ASSEMBLY
BLOWER ASSEMBLY
REPLACEMENT
NT34LR -- COMBUSTION CHAMBER
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
---|---|---|---|---|---|---|
9 | NTP#Â 94-6689 | STAG#Â 73-0041 | CST# | MFR#Â 121407 | APPLIANCE COMPONENTS RV; Screw 8-32 X 3/8 Hex Hd | |
10 | NTP# 41-1291 | STAG# 79-8652 | CST# 67658 | MFR# 231933 | Igniter Electrode; For Suburban Furnace NT-24/ NT-30/ NT-34/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP (Above Serial Number 920500001); Without Gasket; Also Use New Number 525029 | SPECS: 231933 IS A 2 PRONG ELECTRODE (ONE SPARK PROBE AND ONE GROUND PROBE) USED ON NEWER MODELS. FOR NT24/30/34 S/SP & NT40 WITH SERIAL #'S BEG… |
10 | NTP#Â 73-0531 | STAG#Â 73-0531 | CST# | MFR#Â 230949 | APPLIANCE COMPONENTS RV; Ignitor Wire | PER TIM AT SUBURBAN, THIS WIRE ASSM. WILL WORK ON MOST ANY NT MODELS FROM THE YEAR'86 AND UP. IF YOUR ELECTRODE HAS BARBED ENDS, YOU MUST CUT OFF TH... |
10 | NTP#Â 05-3954 | STAG# | CST# | MFR#Â 525029 | Igniter Electrode; For Suburban Furnace NT-24/ NT-30/ NT-34/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP (Above Serial Number 920500001); Without Gasket; Single | |
10 | NTP#Â 07-8794 | STAG# | CST# | MFR#Â 525029MC | Igniter Electrode; For Suburban Furnace Models NT-24/ NT-30/ NT-34/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP (Above Serial Number 920500001); Without Gasket; Replaces 231933MC | |
10 | NTP#Â 73-0587 | STAG#Â 73-0587 | CST# | MFR#Â 231261 | Furnace Wiring Harness; Use With All Suburban Model NT And P Series Electrode Furnaces; 22 Inch Length | |
10 | NTP# | STAG# | CST# | MFR#Â 318060002 | WIRE,HIGH VOLTAGE USE 231713 | |
10 | NTP#Â 73-0766 | STAG#Â 73-0766 | CST# | MFR#Â 231713 | APPLIANCE COMPONENTS RV; Wire Electrode - N.L.A. | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
11 | NTP#Â 94-4249 | STAG# | CST# | MFR#Â 120717 | Nut; For Suburban Furnace NT-12SE/ NT-16SE/ NT-20SE; Fits Furnace Combustion Air Housing; Locking; #10-24 Thread Size | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
12 | NTP#Â 96-0988 | STAG#Â 73-0689 | CST# | MFR#Â 30764 | Furnace Access Door; For Suburban Furnace NT40; Burner Access Panel Assembly | THIS COMES WITH WINDOW AND WINDOW BRACKET ALREADY ATTACHED. |
13 | NTP# | STAG# | CST# | MFR#Â 70163 | GASKET, PILOT BURNER USE 71076 | |
13 | NTP#Â 41-1037 | STAG#Â 79-8646 | CST#Â 65135 | MFR#Â 71076 | Furnace Gasket; Furnace Burner Access Door Gasket And Electrode Gasket; Fits Suburban Furnace NT-12/ NT-16/ NT-20/ NT-12S/ NT-16S/ NT-20S/ NT-12SP/ NT-16SP/ NT-20SP/ NT-24/ NT-30/ NT-34/ NT-24M/ NT-30M/ NT-34M/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP/ NT-40/ P-30/ P-40; Also Use New Number 525011 | |
15 | NTP#Â 69-7881 | STAG#Â 73-0040 | CST# | MFR#Â 121388 | Screw; For Suburban Furnace NT-12SE/ NT-16SE/ NT-20SE; 10 x 1/2; Serrated Head; Single | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
18 | NTP# | STAG# | CST# | MFR#Â 70398 | GASKET,BURNER USE 71076 | IS A USE # FOR 70388 |
18 | NTP#Â 41-1037 | STAG#Â 79-8646 | CST#Â 65135 | MFR#Â 71076 | Furnace Gasket; Furnace Burner Access Door Gasket And Electrode Gasket; Fits Suburban Furnace NT-12/ NT-16/ NT-20/ NT-12S/ NT-16S/ NT-20S/ NT-12SP/ NT-16SP/ NT-20SP/ NT-24/ NT-30/ NT-34/ NT-24M/ NT-30M/ NT-34M/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP/ NT-40/ P-30/ P-40; Also Use New Number 525011 | |
19 | NTP# | STAG# | CST# | MFR#Â 20922 | CHAMBER,COMBUSTION & SHIELD ASSM | IS A USE # FOR 20856,20921 |
20 | NTP#Â 69-9845 | STAG#Â 73-0021 | CST# | MFR#Â 121252 | Screw; For Suburban Furnace NT-Series; Fits Suburban Furnace Combustion Chamber; #10 x 3/8 Inch | |
21 | NTP#Â 41-1170 | STAG#Â 79-8607 | CST#Â 66500 | MFR#Â 230496 | Furnace Limit Switch; For Suburban Furnace P-30S/ NT-34SP/ NT-24/ NT-30/ NT-34/ NT-24M/ NT-30M/ NT-34M/ NT-24S/ NT-30S/ NT-34S | TEMP CUT OFF 225 DEGREES THIS FITS MODELS NT34SP,P30S; NT24/30/34S, NT24/30/34M,NT45S FOR MODEL NT30SP USE 231244 IS A USE # FOR 230839,230612,2307... |
21 | NTP#Â 71-8561 | STAG# | CST# | MFR#Â 230496MC | Furnace Limit Switch; For Suburban Furnace Models P-30S/ NT-34SP/ NT-24/ NT-30/ NT-34/ NT-24M/ NT-30M/ NT-34M/ NT-24S/ NT-30S/ NT-34S | |
22 | NTP#Â 69-9845 | STAG#Â 73-0021 | CST# | MFR#Â 121252 | Screw; For Suburban Furnace NT-Series; Fits Suburban Furnace Combustion Chamber; #10 x 3/8 Inch | |
23 | NTP#Â 41-1022 | STAG#Â 73-0015 | CST# | MFR#Â 120158 | APPLIANCE COMPONENTS RV; #8 Screw | |
24 | NTP#Â 73-0013 | STAG#Â 73-0013 | CST# | MFR#Â 70362 | APPLIANCE COMPONENTS RV; Bushing | |
25 | NTP#Â 69-9845 | STAG#Â 73-0021 | CST# | MFR#Â 121252 | Screw; For Suburban Furnace NT-Series; Fits Suburban Furnace Combustion Chamber; #10 x 3/8 Inch | |
26 | NTP# | STAG# | CST# | MFR#Â 60270 | CLAMP, WIRE | |
27 | NTP#Â 73-0336 | STAG#Â 73-0336 | CST# | MFR#Â 230714 | APPLIANCE COMPONENTS RV; Splicer | |
28 | NTP#Â 69-8246 | STAG#Â 73-1267 | CST# | MFR#Â 121244 | Screw; For Suburban Furnace NT-24SP/ NT-30SP/ NT-34SP; 6 x 1/4 Inch | |
29 | NTP#Â 41-1022 | STAG#Â 73-0015 | CST# | MFR#Â 120158 | APPLIANCE COMPONENTS RV; #8 Screw | |
31 | NTP# | STAG# | CST# | MFR#Â 63248 | APPLIANCE COMPONENTS RV; BRKT PWR SPLY | |
32 | NTP#Â 69-9845 | STAG#Â 73-0021 | CST# | MFR#Â 121252 | Screw; For Suburban Furnace NT-Series; Fits Suburban Furnace Combustion Chamber; #10 x 3/8 Inch | |
33 | NTP#Â 97-2788 | STAG#Â 73-0396 | CST# | MFR#Â 232351 | Furnace Fan Switch; For All V-Series Suburban Furnaces (After Serial Number 952202951) | |
35 | NTP#Â 39-0410 | STAG#Â 80-8633 | CST#Â 64808 | MFR#Â UIBL | Ignition Control Circuit Board; For Coleman/ Duo-Therm/ Hydro-Flame/ Suburban Furnaces And Atwood/ Mor-Flo/ Suburban Water Heaters; 12 Volt DC; With Diagnostic LED; 5.10 Inch Length x 3.43 Inch Width; With Spade Spark Lead Connectors; Fuse And Surge Protected | THIS HAS A SPADE CONNECTION. FOR BOARD WITH SPARK PLUG CONNECTION, USE PART# UIBLPOST THE PART # FOR THE COVER IS LCVR SIZE: 3.43" X 5.10" |
35 | NTP# 39-0400 | STAG# 80-8634 | CST# 64806 | MFR# UIBS | Ignition Control Circuit Board; For Atwood/ Dometic Water Heaters; 12 Volt DC; With Diagnostic LED; 4-1/4 Inch Length x 3-1/4 Inch Width; With Spade Spark Lead Connectors/ Adapter Kit; Fuse And Surge Protected; 2 TAB MOUNTING KIT For Atwood ®/ Hydroflame ® Water Heaters Sold Separately | SPECIFICATIONS: THIS HAS A SPADE CONNECTION. |
35 | NTP# 42-0579 | STAG# 80-8552 | CST# 62345 | MFR# 520741 | Ignition Control Circuit Board; For Suburban Furnace SF Series/ NT Series And All Water Heater DSI Series/ SW Series/ VDSI Series; Also Use New Number 521099 For Furnaces Or 520814 For Water Heaters | CURRENT REPLACEMENT INFORMATION (OLD SERIAL # BREAKS LISTED BELOW): FOR WATER HEATERS – 520741 IS REPLACED BY 520814 AND THE PLASTIC BOARD COVER… |
35 | NTP#Â 41-0052 | STAG#Â 80-8534 | CST#Â 64159 | MFR#Â 521099 | Ignition Control Circuit Board; Replacement For Suburban 520741 Or 520820 Boards And Fits All Suburban 12 Volt Furnaces; Will Not Replace 24 Volt AC Boards | **Updated information on Furnace models this will fit. Feb 2014** The 521099 plugs (wiring harness & electrode wire) into any Suburban 12 VDC fur... |
35 | NTP#Â 69-9860 | STAG#Â 73-0490 | CST# | MFR#Â 232161 | Furnace Wiring Harness; For Suburban Furnace DD17DSI/ NT-Series | |
35 | NTP# | STAG# | CST# | MFR#Â 231741 | BOARD,MODULE USE 520741 | THE 231741 BOARD IS FOR THE SF SERIES. THE 520612 BOARD IS FOR THE NT45M & NT45S SERIES. THE 520741 BOARD IS FOR ALL 12V WATER HEATERS AND FURNACE... |
35 | NTP#Â 41-0053 | STAG#Â 80-8673 | CST#Â 66584 | MFR#Â FAN50PLUS | Ignition Control Circuit Board; Replaces Dinosaurs Earlier Small And Large Fan Boards; Can Also Be Used To Replace The Present Fan Control Ignitor Boards Being Used By Suburban\ Atwood\ Hydroflame | IS A USE# FOR UIBFCS FOR SUBURBAN OR HYDROFLAME'S FAN CONTROL BOARDS. THIS WORKS IN FURNACES THAT HAVE THE FAN CONTROL FEATURE, AND CAN ALSO BE USED... |
35 | NTP#Â 39-0425 | STAG#Â 80-8642 | CST#Â 64817 | MFR#Â LCVR | Ignition Control Circuit Board Cover; Replacement For Dinosaurs Universal Igniter Boards; Large; White; Fire Retardant ABS Plastic | |
35 | NTP# 39-0405 | STAG# 80-8636 | CST# 64807 | MFR# UIBSPOST | Ignition Control Circuit Board; For Atwood Water Heaters/ Norcold And Servel Refrigerators; Small; 4-1/4 Inch Length x 3-1/4 Inch Width; With Post Top; 2 TAB MOUNTING KIT For Atwood ®/ Hydroflame ® Water Heaters Sold Separately | |
35 | NTP# 39-0415 | STAG# 80-8637 | CST# 64809 | MFR# UIBLPOST | Ignition Control Circuit Board; For Coleman/ Duo-Therm/ Hydro-Flame/ Suburban Furnaces And Atwood/ Mor-Flo/ Suburban Water Heaters; 12 Volt DC; With Diagnostic LED; 4-1/4 Inch Length x 3-1/4 Inch Width; With Post Spark Lead Connectors; Fuse And Surge Protected | THIS HAS A SPARK PLUG CONNECTION. <... |
35 | NTP#Â 39-0420 | STAG#Â 80-8641 | CST#Â 64816 | MFR#Â SMALLCOVER | Ignition Control Circuit Board Cover; Replacement For Dinosaurs Universal Igniter Boards; Small; White; Fire Retardant ABS Plastic | |
36 | NTP#Â 73-0006 | STAG#Â 73-0006 | CST# | MFR#Â 121357 | APPLIANCE COMPONENTS RV; Screw 6 X 5/8 Ph Ph | |
38 | NTP#Â 69-9860 | STAG#Â 73-0490 | CST# | MFR#Â 232161 | Furnace Wiring Harness; For Suburban Furnace DD17DSI/ NT-Series | |
38 | NTP# | STAG# | CST# | MFR#Â 3000003 | BURNER, LARGE W/AIR SHUTTER USE 520564 | |
38 | NTP# 42-0579 | STAG# 80-8552 | CST# 62345 | MFR# 520741 | Ignition Control Circuit Board; For Suburban Furnace SF Series/ NT Series And All Water Heater DSI Series/ SW Series/ VDSI Series; Also Use New Number 521099 For Furnaces Or 520814 For Water Heaters | CURRENT REPLACEMENT INFORMATION (OLD SERIAL # BREAKS LISTED BELOW): FOR WATER HEATERS – 520741 IS REPLACED BY 520814 AND THE PLASTIC BOARD COVER… |
38 | NTP#Â 41-0052 | STAG#Â 80-8534 | CST#Â 64159 | MFR#Â 521099 | Ignition Control Circuit Board; Replacement For Suburban 520741 Or 520820 Boards And Fits All Suburban 12 Volt Furnaces; Will Not Replace 24 Volt AC Boards | **Updated information on Furnace models this will fit. Feb 2014** The 521099 plugs (wiring harness & electrode wire) into any Suburban 12 VDC fur... |
38 | NTP#Â 72-0691 | STAG#Â 72-0691 | CST# | MFR#Â 520820MC | Ignition Control Circuit Board; Use With Suburban NT-12-S/ SF-42/ NT-25-K Furnace Models; 12 Volt DC | |
38 | NTP#Â 41-1227 | STAG#Â 73-0723 | CST# | MFR#Â 520839 | Furnace Wiring Harness; For Suburban Furnace NT-24SP/ NT-30SP/ NT-34SP/ NT-40 | THIS IS USED TO CONVERT NON-FAN CONTROL MODULE BOARD FURNACES. THIS PART # IS USED ON NT24/30/34SP/40 MODELS ONLY THE BOARD IS SEPARATE; USE 52082... |
38 | NTP# 39-0400 | STAG# 80-8634 | CST# 64806 | MFR# UIBS | Ignition Control Circuit Board; For Atwood/ Dometic Water Heaters; 12 Volt DC; With Diagnostic LED; 4-1/4 Inch Length x 3-1/4 Inch Width; With Spade Spark Lead Connectors/ Adapter Kit; Fuse And Surge Protected; 2 TAB MOUNTING KIT For Atwood ®/ Hydroflame ® Water Heaters Sold Separately | SPECIFICATIONS: THIS HAS A SPADE CONNECTION. |
38 | NTP#Â 39-0410 | STAG#Â 80-8633 | CST#Â 64808 | MFR#Â UIBL | Ignition Control Circuit Board; For Coleman/ Duo-Therm/ Hydro-Flame/ Suburban Furnaces And Atwood/ Mor-Flo/ Suburban Water Heaters; 12 Volt DC; With Diagnostic LED; 5.10 Inch Length x 3.43 Inch Width; With Spade Spark Lead Connectors; Fuse And Surge Protected | THIS HAS A SPADE CONNECTION. FOR BOARD WITH SPARK PLUG CONNECTION, USE PART# UIBLPOST THE PART # FOR THE COVER IS LCVR SIZE: 3.43" X 5.10" |
38 | NTP# | STAG# | CST# | MFR#Â 231427 | BOARD,MODULE | USE 231741 FOR ALL SF SERIES. USE 520612 FOR THE NT45M & NT45S. USE 520741 FOR THE 12V WATER HEATER AND FURNACES EXCEPT FOR MODELS LISTED ABOVE. |
38 | NTP#Â 39-0420 | STAG#Â 80-8641 | CST#Â 64816 | MFR#Â SMALLCOVER | Ignition Control Circuit Board Cover; Replacement For Dinosaurs Universal Igniter Boards; Small; White; Fire Retardant ABS Plastic | |
38 | NTP# 39-0415 | STAG# 80-8637 | CST# 64809 | MFR# UIBLPOST | Ignition Control Circuit Board; For Coleman/ Duo-Therm/ Hydro-Flame/ Suburban Furnaces And Atwood/ Mor-Flo/ Suburban Water Heaters; 12 Volt DC; With Diagnostic LED; 4-1/4 Inch Length x 3-1/4 Inch Width; With Post Spark Lead Connectors; Fuse And Surge Protected | THIS HAS A SPARK PLUG CONNECTION. <... |
38 | NTP#Â 39-0425 | STAG#Â 80-8642 | CST#Â 64817 | MFR#Â LCVR | Ignition Control Circuit Board Cover; Replacement For Dinosaurs Universal Igniter Boards; Large; White; Fire Retardant ABS Plastic | |
38 | NTP# 39-0405 | STAG# 80-8636 | CST# 64807 | MFR# UIBSPOST | Ignition Control Circuit Board; For Atwood Water Heaters/ Norcold And Servel Refrigerators; Small; 4-1/4 Inch Length x 3-1/4 Inch Width; With Post Top; 2 TAB MOUNTING KIT For Atwood ®/ Hydroflame ® Water Heaters Sold Separately | |
38 | NTP#Â 41-0053 | STAG#Â 80-8673 | CST#Â 66584 | MFR#Â FAN50PLUS | Ignition Control Circuit Board; Replaces Dinosaurs Earlier Small And Large Fan Boards; Can Also Be Used To Replace The Present Fan Control Ignitor Boards Being Used By Suburban\ Atwood\ Hydroflame | IS A USE# FOR UIBFCS FOR SUBURBAN OR HYDROFLAME'S FAN CONTROL BOARDS. THIS WORKS IN FURNACES THAT HAVE THE FAN CONTROL FEATURE, AND CAN ALSO BE USED... |
38 | NTP# 41-1274 | STAG# 80-8557 | CST# 65170 | MFR# 520820 | Ignition Control Circuit Board; Replacement For Suburban Furnace SF-Series (After Serial Number 003805481); 12 Volt DC | CURRENT REPLACEMENT INFORMATION (OLD SERIAL # BREAKS LISTED BELOW: FOR FURNACES - 520820 HAS BEEN REPLACED BY 521099. SPECS: RE… |
38 | NTP#Â 42-0510 | STAG#Â 79-8732 | CST#Â 60412 | MFR#Â 520564 | Water Heater Burner; Large; For Suburban Water Heater SSRV6/ SSRV6M/ ESSRV6/ SSRV8/ SSRV8M/ ESSRV8/ SSRV10/ SSRV10M/ ESSWRV10/ 10ARVM/ E10ARV; With Target/ Burner Support Bracket/ Shutter/ Screw/ Nut/ Pilot Bracket/ Pilot Burner/ Thermocouple/ Tube/ Tube Fitting | |
38 | NTP#Â 73-0304 | STAG#Â 73-0304 | CST# | MFR#Â 70807 | APPLIANCE COMPONENTS RV; Insul Mod Board | FITS : SW6DM USE WITH 231427 BOARD |
38 | NTP# | STAG# | CST# | MFR#Â 231741 | BOARD,MODULE USE 520741 | THE 231741 BOARD IS FOR THE SF SERIES. THE 520612 BOARD IS FOR THE NT45M & NT45S SERIES. THE 520741 BOARD IS FOR ALL 12V WATER HEATERS AND FURNACE... |
39 | NTP#Â 73-0465 | STAG#Â 73-0465 | CST# | MFR#Â 90301 | APPLIANCE COMPONENTS RV; Panel Mod Board | |
40 | NTP#Â 42-0063 | STAG# | CST# | MFR#Â 12VDCTDR | Furnace Time Delay Relay; Replacement For Older Furnaces That Use A Standard 12 Volt DC Igniter Board; Micro Controlled; 12 Volt DC; 1-1/2 Inch x 1-1/2 Inch; 4 Second Delay; 2 Minute Cool Down Period At The End Of The Heat Cycle | RELAY USED ON MODELS PRIOR TO JANUARY 2006 AND WAS INSTALLED SEPARATELY FROM THE IGNITION CONTROL. AFTER JANUARY 2006, THE RELAY IS PART OF THE IGNITI... |
40 | NTP#Â 41-1224 | STAG#Â 50-0515 | CST#Â 61348 | MFR#Â 521069 | Furnace Time Delay Relay; For Suburban Furnace NT-12S/ NT-16S/ NT-20S/ NT-12SE/ NT-16SE/ NT-20SE/ NT-25/ NT-30/ NT-35/ SF-20/ SF-25/ SF-30/ SF-35/ SF-42/ SF-20F/ SF-25F/ SF-30F/ SF-35F/ SF-42F/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP/ NT-40 (NT24/30/34 S And SP Only Above Serial Number 1600851); 12 Volt | |
40 | NTP#Â 79-8713 | STAG#Â 79-8713 | CST# | MFR#Â 231202 | APPLIANCE COMPONENTS RV; Relay Switch | Suburban is offering a replacement for this switch. It is part #521069 (50-0515). SUGGESTED ALTERNATE: OPTION 1: DINOSAUR ELECTRONICS P#48000D (80-... |
40 | NTP#Â 41-0035 | STAG#Â 80-8646 | CST# | MFR#Â 48000D | Furnace Time Delay Relay; Replacement For Older Furnaces That Use A Standard 12 Volt DC Igniter Board; Micro Controlled; 12 Volt DC; 1-1/2 Inch x 1-1/2 Inch; 4 Second Delay; 2 Minute Cool Down Period At The End Of The Heat Cycle; Also Use New Number 12VDCTDR | |
40 | NTP#Â 69-9284 | STAG#Â 79-8829 | CST# | MFR#Â 231202MC | Furnace Time Delay Relay; Use With Suburban Furnace Models NT-24-S/ NT-24-SP/ NT-30-S/ NT-30-SP/ NT-34-S/ NT-40/ P-30-S/ P-40-S; 24 Volt | ONLY FOR USE WITH 520741 BOARDS. THE NEW BOARD, 520820, HAS THE TIME DELAY RELAY BUILT IN TO THE BOARD.SUGGESTED ALTERNATE TO SUBURBAN 231202 RELAY T... |
41 | NTP#Â 73-0043 | STAG#Â 73-0043 | CST# | MFR#Â 121502 | APPLIANCE COMPONENTS RV; Screw 6X3/8 Ph Rh Black | |
42 | NTP# | STAG# | CST# | MFR#Â 260542 | VENT CAP USE 79-8143 | REPLACES: IS A USE # FOR 260164 |
42 | NTP# | STAG# | CST# | MFR#Â 260164 | ***USE 79-8142*** | IS A USE # FOR 260111, 260096. THE INTAKE TUBE DOES NOT COME WITH THIS. THE PART # IS 50906. |
43 | NTP# 71-8388 | STAG# 71-8388 | CST# | MFR# 052159 | Furnace Intake Tube; For Suburban Furnace NT12S/ NT-16S/ NT-20S/ NT-16SQ/ NT-20SQ/ NT-30SP/ NT-34SP; 3 Inch Length | THIS IS A COMPOSITE TUBE AND DOES NOT USE A GASKET. SUBURBAN'S ORIGINAL TUBE WAS STEEL THAT REQUIRED A GASKET. THE ORIGINAL STEEL TU... |
43 | NTP# 41-1014 | STAG# 73-0627 | CST# | MFR# 50906 | Furnace Intake Tube; For Suburban Furnace NT12S/ NT-16S/ NT-20S/ NT-16SQ/ NT-20SQ/ NT-30SP/ NT-34SP; 3 Inch Length; With Gasket | THIS IS A STEEL TUBE AND USES A GASKET. SUBURBAN IS CHANGING OVER TO A COMPOSITE TUBE THAT DOES NOT REQUIRE A GASKET. THE COMPOSITE TUBE I... |
45 | NTP#Â 73-0048 | STAG#Â 73-0048 | CST# | MFR#Â 121853 | Screw; For Use With Suburban Furnace Vent NT.12SE/ NT-16SE/ NT-20SE; #10 x 3/4 | |
46 | NTP#Â 41-1033 | STAG#Â 73-0246 | CST# | MFR#Â 121711 | Screw; For Suburban Furnace Exhaust Vent; 8 X 3-1/4; Set Of 2 | IS A USE # FOR 121249, 121256 |
999 | NTP#Â 69-9868 | STAG#Â 73-0751 | CST#Â 60382 | MFR#Â 520797 | Furnace Gasket; For Suburban Furnace NT 24/ NT 30/ NT 34/ NT 24SP/ NT 30SP/ NT 34SP/ NT 40/ P30S/ P40 | KIT CONTAINS: GASKETS FOR ELECTRODE,MOTOR,CROSSOVER TUBE,BURNER DOOR ,AIR INTAKE & MOTOR MOUNT,MANIFOLDx2 AND COMBUSTION AIR CHAMBER. |
999 | NTP#Â 73-0531 | STAG#Â 73-0531 | CST# | MFR#Â 230949 | APPLIANCE COMPONENTS RV; Ignitor Wire | PER TIM AT SUBURBAN, THIS WIRE ASSM. WILL WORK ON MOST ANY NT MODELS FROM THE YEAR'86 AND UP. IF YOUR ELECTRODE HAS BARBED ENDS, YOU MUST CUT OFF TH... |
999 | NTP#Â 30-2357 | STAG# | CST# | MFR#Â 231827 | APPLIANCE COMPONENTS RV; BUSHING SNAP | |
999 | NTP#Â 73-0766 | STAG#Â 73-0766 | CST# | MFR#Â 231713 | APPLIANCE COMPONENTS RV; Wire Electrode - N.L.A. | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
999 | NTP#Â 41-1266 | STAG#Â 79-8143 | CST#Â 61339 | MFR#Â 260573 | Furnace Vent; For Suburban Furnace NT-30 SP/ NT-24SP/ NT-34SP; Exhaust Vent; With Vent Cap | |
999 | NTP# | STAG# | CST# | MFR#Â 318060002 | WIRE,HIGH VOLTAGE USE 231713 | |
999 | NTP#Â 73-0587 | STAG#Â 73-0587 | CST# | MFR#Â 231261 | Furnace Wiring Harness; Use With All Suburban Model NT And P Series Electrode Furnaces; 22 Inch Length | |
999 | NTP#Â 73-0212 | STAG#Â 73-0212 | CST# | MFR#Â 230218 | APPLIANCE COMPONENTS RV; Bushing Snap 7/8" | PART REPLACED BY 231827 |
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
Item:
NTP:
Stag:
Coast:
MFR:
Part Description:
Part Notes:
NT34LR -- CABINET ASSEMBLY
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
---|---|---|---|---|---|---|
1 | NTP# | STAG# | CST# | MFR#Â 100962 | CABINET ASM USE 101874 | IS A USE # FOR X100962,100859 |
1 | NTP#Â 69-9844 | STAG#Â 73-1080 | CST# | MFR#Â 101874 | Furnace Cabinet; Replacement Cabinet For Suburban Furnace N30M/ NT-20T/ NT-24MA/ NT-24MP/ NT-24MPD/ NT-24S/ NT-24SP/ NT-34MA/ NT-30MP/ NT-30MPD/ NT-30S/ NT-30SP/ NT-34L/ NT-34LD/ NT-34S/ NT-34SP | IS A USE # FOR 100962 |
2 | NTP#Â 79-8752 | STAG#Â 79-8752 | CST# | MFR#Â 121662 | APPLIANCE COMPONENTS RV; Sububan Tinnerman Fastene | THIS IS WHAT THE SCREW FASTENS INTO ON THE DOOR. IT IS COMMONLY CALLED A CLIP. |
2 | NTP#Â 41-1018 | STAG#Â 50-0799 | CST#Â 61306 | MFR#Â 122060 | Stove Mounting Bracket; For Suburban Range; Angled; Single | |
3 | NTP#Â 41-1028 | STAG#Â 73-0341 | CST#Â 63997 | MFR#Â 62164 | Furnace Gasket; Furnace Bottom Duct Adapter Gasket; Fits Suburban Furnace NT-24/ NT-30/ NT-34S/ NT-24/ NT-30SP/ NT-25/ NT-30/ NT-35K/ NT-24/ NT-30/ NT-34HS/ P-30S | |
4 | NTP#Â 69-7881 | STAG#Â 73-0040 | CST# | MFR#Â 121388 | Screw; For Suburban Furnace NT-12SE/ NT-16SE/ NT-20SE; 10 x 1/2; Serrated Head; Single | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
5 | NTP# | STAG# | CST# | MFR#Â 100808 | FRONT,CABINET GRAY ***SEE NOTES FOR USE #'S | PER SUBURBAN WE WILL BE GETTING THEM IN GRAY THERE ARE 2 COLORS OF GRAY. LIGHT AND DARK. BOTH ARE OK AS THEY ARE NOT SEEN. PL 12-23-97 |
5 | NTP#Â 94-5774 | STAG# | CST# | MFR#Â 101873 | APPLIANCE COMPONENTS RV; Suburban Cabinet Front | |
5A | NTP#Â 73-0038 | STAG#Â 73-0038 | CST# | MFR#Â 121224 | APPLIANCE COMPONENTS RV; Screw 10 X 3/4 Ph Ph | FITS MODELS: (SF)20F-25F-30F-35F PER SUBURBAN TECH THIS SCREW WILL WORK IN PLACE OF THE #8 X 3/4 SCREW ITS A LITTLE LARGER BUT WILL WORK 11/03 4- REQ... |
6 | NTP#Â 41-1005 | STAG#Â 79-8695 | CST#Â 68421 | MFR#Â 50715 | Furnace Duct Collar; For Use With All Suburban Furnaces Except GT And DD Models; 4 Inch Round | FITS MODELS: NT30K-SF20F/25F/30F/35F 000000000050819 |
7 | NTP#Â 69-8026 | STAG#Â 79-8870 | CST# | MFR#Â 1F87R875 | Wall Thermostat; Single Stage; For Heat And Cool Control; Programmable; Digital Display; 24 Volt; Battery Powered | |
7 | NTP# 69-8025 | STAG# 79-8594 | CST# | MFR# 01C20102S1 | Wall Thermostat; Single Stage; Snap-Action; Low Voltage; Heat Only; 24 Volt; White | SPECIFICATIONS: 1 Heat, 0 Cool 24 Volts Snap-Action Heat Only (No Switch) Profile-Vertical Rounded Range 50-90° F MERCURY FREE |
7 | NTP#Â 69-8027 | STAG#Â 79-8871 | CST# | MFR#Â 1F80R850 | APPLIANCE COMPONENTS RV; Thermostat 3 Day Program | |
7 | NTP#Â 08-0110 | STAG#Â 79-8592 | CST# | MFR#Â 1C20101 | Wall Thermostat; Heat Only; Mechanical; 1 Stage; White; | SPECIFICATIONS: 1 Heat, 0 Cool 24 Volts Snap-Action Lowest Temperature Setting Is "Off" Position (No Switch) Heat Only Profile-Vertical Rounded R... |
7 | NTP#Â 41-1068 | STAG#Â 79-8622 | CST#Â 69862 | MFR#Â 161154 | Wall Thermostat; Single Stage; For Heat Control; Mechanical Readout; White Case | |
7 | NTP#Â 08-0114 | STAG#Â 45-0076 | CST# | MFR#Â 100402 | Wall Thermostat; Single Stage; For Heat/ Cool Control; Mechanical Readout; 12 Volt; Without Fan Speed Control; Without Fan On Mode | THIS T-STAT HAS A HEAT ANTICIPATOR IF YOU NEED A WALL T-STAT WITH OUT ANTICIPATOR USE PART# 100-502 100402 HAS A POSITIVE OFF LEVER. FITS MODELS: S... |
7 | NTP# | STAG# | CST# | MFR#Â 160849 | T-STAT USE 161154 | |
8 | NTP#Â 41-1010 | STAG#Â 79-8696 | CST#Â 68415 | MFR#Â 520322 | Furnace Power Supply Wiring Harness; For Suburban Furnace; With 3-Pin Female Connector | INTERIOR HARNESS (MALE) USE # 520323 |
999 | NTP#Â 94-6306 | STAG#Â 49-9068 | CST# | MFR#Â 520973 | Furnace Vent Extension; For Suburban NT-24SP/ NT-30SP/ NT-34SP/ P-30S; 3-1/8 Inch To 4-7/8 Inch Extension Length | |
999 | NTP#Â 70-6954 | STAG#Â 47-1912 | CST# | MFR#Â 520501S | APPLIANCE COMPONENTS RV; Kit Vent | |
999 | NTP# | STAG# | CST# | MFR#Â 520930 | EXTENSION KIT,TUBE 2 1/4"-3 1/8" | REPLACES: IS A USE # FOR 520498 |
999 | NTP#Â 70-6953 | STAG#Â 47-1903 | CST# | MFR#Â 520499 | APPLIANCE COMPONENTS RV; Kit Vent | |
999 | NTP#Â 94-9955 | STAG#Â 47-1908 | CST# | MFR#Â 520500 | APPLIANCE COMPONENTS RV; Extension Tube | THIS EXTENDS FROM 4 7/8" TO 7" LONG |
999 | NTP#Â 41-1009 | STAG#Â 79-8745 | CST#Â 61474 | MFR#Â 50733 | Furnace Duct Cover Plate; Fits Suburban 4 Inch Duct | FITS MODELS: NT30K-SF20F/25F/30F/35F 000000000050819 |
999 | NTP#Â 69-7409 | STAG#Â 45-8146 | CST# | MFR#Â 260089 | Furnace Vent Adapter; Replacement For Suburban Furnace NT-20T/ NT24S/ NT24SP/ NT-30M/ NT-30S/ NT-30SP/ NT-34S/ NT-34SP/ P-30S | THIS GOES WITH 260164 |
999 | NTP# | STAG# | CST# | MFR#Â 520931 | EXTENSION , TUBE USE 520973 3 1/8"-4 7/8" | REPLACES: IS A USE # FOR 520499 |
999 | NTP#Â 70-6952 | STAG#Â 47-1902 | CST# | MFR#Â 520498 | APPLIANCE COMPONENTS RV; Extension Kit Tube 2 1/4- | |
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
Item:
NTP:
Stag:
Coast:
MFR:
Part Description:
Part Notes:
NT34LR -- BURNER ASSEMBLY
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
---|---|---|---|---|---|---|
22 | NTP#Â 69-9845 | STAG#Â 73-0021 | CST# | MFR#Â 121252 | Screw; For Suburban Furnace NT-Series; Fits Suburban Furnace Combustion Chamber; #10 x 3/8 Inch | |
47 | NTP# 41-1291 | STAG# 79-8652 | CST# 67658 | MFR# 231933 | Igniter Electrode; For Suburban Furnace NT-24/ NT-30/ NT-34/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP (Above Serial Number 920500001); Without Gasket; Also Use New Number 525029 | SPECS: 231933 IS A 2 PRONG ELECTRODE (ONE SPARK PROBE AND ONE GROUND PROBE) USED ON NEWER MODELS. FOR NT24/30/34 S/SP & NT40 WITH SERIAL #'S BEG… |
47 | NTP#Â 05-3954 | STAG# | CST# | MFR#Â 525029 | Igniter Electrode; For Suburban Furnace NT-24/ NT-30/ NT-34/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP (Above Serial Number 920500001); Without Gasket; Single | |
47 | NTP#Â 07-8794 | STAG# | CST# | MFR#Â 525029MC | Igniter Electrode; For Suburban Furnace Models NT-24/ NT-30/ NT-34/ NT-24S/ NT-30S/ NT-34S/ NT-24SP/ NT-30SP/ NT-34SP (Above Serial Number 920500001); Without Gasket; Replaces 231933MC | |
48 | NTP# | STAG# | CST# | MFR#Â 10619 | BURNER,STAINLESS USE 10701 | FOR CAST IRON BURNER USE PART # 10609. PER BILL EWING 11/12/01: THE STAINLESS STEAL BURNER WILL NOT REPLACE THE CAST IRON BURNER. |
48 | NTP#Â 96-0987 | STAG#Â 73-0980 | CST# | MFR#Â 10701 | APPLIANCE COMPONENTS RV; Suburban Burner Assy | IS A USE # FOR 10619 |
49 | NTP#Â 95-6536 | STAG#Â 73-0237 | CST# | MFR#Â 180222 | Furnace Burner Orifice; For Suburban Furnace NT-34/ NT-34M/ NT-34S/ NT-34SP/ NT-35K/ SF-35/ SF-35F | IS A USE # FOR 180242 |
50 | NTP#Â 99-2881 | STAG#Â 73-0293 | CST# | MFR#Â 70408 | Furnace Gasket; Furnace Manifold Gasket; Fits Suburban Furnace NT-24SP/ NT-30SP/ NT-34SP/ NT-40/ P-30S/ P-40/ P-40B | REPLACES: IS A USE # FOR 70387 |
51 | NTP#Â 69-7881 | STAG#Â 73-0040 | CST# | MFR#Â 121388 | Screw; For Suburban Furnace NT-12SE/ NT-16SE/ NT-20SE; 10 x 1/2; Serrated Head; Single | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
52 | NTP# | STAG# | CST# | MFR#Â 170757 | MANIFOLD ASM ***USE 73-0833*** | X170757 |
53 | NTP# | STAG# | CST# | MFR#Â 160832 | VALVE,GAS USE 161078 | |
53 | NTP#Â 41-1061 | STAG#Â 79-8631 | CST#Â 68435 | MFR#Â 161123 | Furnace Gas Valve; For Use With Suburban Furnace NT-12S/ NT-12SE/ NT-16S/ NT-16SE/ NT-20S/ NT-20SE/ NT-24S/ NT-24SP/ NT-24M/ NT-25K/ NT-30S/ NT-30SP/ NT-30M/ NT-30K/ NT-34S/ NT-34SP/ NT-35K/ NT-40/ NT-42T | |
53 | NTP# | STAG# | CST# | MFR#Â 161078 | VALVE, GAS USE 161123 | |
54 | NTP# | STAG# | CST# | MFR#Â 170858S | PIPE,GAS INLET - Obsolete | |
56 | NTP#Â 73-0197 | STAG#Â 73-0197 | CST# | MFR#Â 70432 | Furnace Gasket; Furnace Gas Inlet Tube Gasket; Fits Suburban Furnace NT-45S | |
57 | NTP#Â 73-0395 | STAG#Â 73-0395 | CST# | MFR#Â 170082 | APPLIANCE COMPONENTS RV; Elbow 90 Deg | |
58 | NTP#Â 73-0158 | STAG#Â 73-0158 | CST# | MFR#Â 70534 | Furnace Gasket; Furnace Disk Cover Gasket; Fits Suburban Furnace NT-20T/ NT-23M/ NT-24M/ NT-24MD/ NT-24S/ NT-24SP/ NT-30M/ NT-30MD/ NT-30S/ NT-30SP/ NT-34MM/ NT-34MMD/ NT-34S/ NT-34SP/ P-30S/ P-45S/ NT-45SE | |
59 | NTP#Â 73-0270 | STAG#Â 73-0270 | CST# | MFR#Â 62408 | APPLIANCE COMPONENTS RV; Disc Cov Gas Inlet | |
60 | NTP# | STAG# | CST# | MFR#Â 160740 | VALVE,SHUTOFF | |
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
Item:
NTP:
Stag:
Coast:
MFR:
Part Description:
Part Notes:
NT34LR -- BLOWER ASSEMBLY
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
---|---|---|---|---|---|---|
61 | NTP#Â 95-3525 | STAG#Â 73-0876 | CST# | MFR#Â 350113 | Furnace Blower Wheel; For Suburban Furnace NT-30SP/ NT-34SP | 350076 |
61 | NTP# | STAG# | CST# | MFR#Â 350076 | WHEEL,ROOM AIR USE 350113 | |
62 | NTP#Â 69-9845 | STAG#Â 73-0021 | CST# | MFR#Â 121252 | Screw; For Suburban Furnace NT-Series; Fits Suburban Furnace Combustion Chamber; #10 x 3/8 Inch | |
63 | NTP#Â 69-8241 | STAG#Â 73-1061 | CST# | MFR#Â 390283 | Furnace Blower Housing; Furnace Blower Wheel Housing; For Suburban Furnace NT30SP/ NT34SP | |
64 | NTP#Â 70-4567 | STAG#Â 45-1425 | CST# | MFR#Â 121227 | Screw; Use With Suburban Furnace Model NT40; Phillips Head; 10-24 x 1/2 | |
65 | NTP# | STAG# | CST# | MFR#Â 233356 | Furnace Low Air Flow Switch; For Suburban Furnace NT-30/ NT-34/ NT-30M/ NT-34M/ NT-30S/ NT-34S/ NT-30SP/ NT-34SP/ NT-25/ NT-30/ NT-35/ NT-35K/ P-30S/ SF-20/ SF-25/ SF-30/ SF-35/ SF-20F/ SF-25F/ SF-30F/ SF-35F; Also Use New Number 525024 | |
65 | NTP#Â 41-1320 | STAG#Â 73-0529 | CST# | MFR#Â 232279 | Furnace Low Air Flow Switch; For Suburban Furnace NT-40; Also Use New Number 233355 | |
65 | NTP#Â 07-7768 | STAG# | CST# | MFR#Â 233355 | Furnace Low Air Flow Switch; For Suburban Furnace NT-40 | |
65 | NTP#Â 39-0134 | STAG# | CST# | MFR#Â 230509MC | Furnace Low Air Flow Switch; For Suburban Furnace Models NT-30/ NT-34/ NT-30M/ NT-34M/ NT-30S/ NT-34S/ NT-30SP/ NT-34SP/ NT-25/ NT-30/ NT-35/ NT-35K/ P-30S/ SF-20/ SF-25/ SF-30/ SF-35/ SF-20F/ SF-25F/ SF-30F/ SF-35F | |
65 | NTP#Â 41-0992 | STAG#Â 79-8610 | CST#Â 68406 | MFR#Â 230509 | Furnace Low Air Flow Switch; For Suburban Furnace NT-30/ NT-34/ NT-30M/ NT-34M/ NT-30S/ NT-34S/ NT-30SP/ NT-34SP/ NT-25/ NT-30/ NT-35/ NT-35K/ P-30S/ SF-20/ SF-25/ SF-30/ SF-35/ SF-20F/ SF-25F/ SF-30F/ SF-35F; Also Use New Number 233356 | REPLACES: IS A USE# FOR 230891SPECS: IF ORDERING FOR NT24M USE PART NUMBER 230510 INSTEAD. ORDER SCREWS SEPERATELY-2 OF 121652 AND 2 OF 121247. FO... |
66 | NTP#Â 70-4568 | STAG#Â 45-1427 | CST# | MFR#Â 121247 | Screw; Use With Suburban Furnace Part Numbers NT-16SE/ NT-20SE; # 2; 56 Inch x 5/8 Inch; Hex Head | IT TAKES 2 OF THESE FOR THE SAIL SWITCH ASSY. |
67 | NTP#Â 73-0023 | STAG#Â 73-0023 | CST# | MFR#Â 121364 | APPLIANCE COMPONENTS RV; Washer Lock #2 | |
68 | NTP# | STAG# | CST# | MFR#Â 120672 | NUT HEX 2-56 | |
69 | NTP#Â 69-7881 | STAG#Â 73-0040 | CST# | MFR#Â 121388 | Screw; For Suburban Furnace NT-12SE/ NT-16SE/ NT-20SE; 10 x 1/2; Serrated Head; Single | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
70 | NTP#Â 69-8142 | STAG#Â 73-0451 | CST# | MFR#Â 62138 | Furnace Motor Bracket; For Suburban NT-40 | IS A USE # FOR 62196 |
71 | NTP#Â 94-4249 | STAG# | CST# | MFR#Â 120717 | Nut; For Suburban Furnace NT-12SE/ NT-16SE/ NT-20SE; Fits Furnace Combustion Air Housing; Locking; #10-24 Thread Size | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
72 | NTP#Â 41-1031 | STAG#Â 79-8541 | CST#Â 67653 | MFR#Â 70385 | Furnace Gasket; Furnace Crossover Tube Gasket; Fits Suburban Furnace NT-24M/ NT-30M/ NT-30SP/ NT-34SP/ NT-40 | |
73 | NTP#Â 73-0505 | STAG#Â 73-0505 | CST# | MFR#Â 50751 | APPLIANCE COMPONENTS RV; Tube Crossover | IS A USE # FOR 50439 |
74 | NTP#Â 69-7881 | STAG#Â 73-0040 | CST# | MFR#Â 121388 | Screw; For Suburban Furnace NT-12SE/ NT-16SE/ NT-20SE; 10 x 1/2; Serrated Head; Single | THE HIGH ALTITUDE ORIFICE FOR NT16SE IS 180225 |
75 | NTP# 41-1245 | STAG# 79-8617 | CST# 69868 | MFR# 231208 | Furnace Motor; For Suburban Furnace NT-34M/ NT-34S/ NT-34SP/ NT-40S/ NT-42S/ NT-42T | IS A USE # FOR 230744, 231381, PE2716Q, FITS: NT30HS/HS/MA, NT34M/MD/MM/S/HS/L, NT42T/S, NT34SP, NT40 # ON MOTOR IS PE27087Q OR PE27099Q 11.6 V … |
75 | NTP# 42-0824 | STAG# 49-2737 | CST# | MFR# 231208MC | Furnace Motor; For Suburban Furnace Models NT-34M/ NT-34S/ NT-34SP/ NT-40S/ NT-42S/ NT-42T; Also Use New Number 521138MC | SUGGESTED ALTERNATE: THIS PART IS NOT AN OE ORIGINAL BUT CAN BE USED AS AN ALTERNATE P#231208. SINCE THIS IS NOT AN ORIGINAL PART, IT SHOULD… |
75 | NTP# | STAG# | CST# | MFR#Â PE2787Q | MOTOR, BLOWER (169) 231208 | IS A USE # FOR 231208, 230744, 231381, PE2716Q |
75 | NTP#Â 73-0008 | STAG# | CST# | MFR#Â 521138 | Furnace Motor; Use With Suburban Furnaces NT-34 M/ S/ SP NT-40; 12 Volt DC | |
76 | NTP#Â 90-1652 | STAG#Â 73-0287 | CST# | MFR#Â 70384 | Furnace Gasket; Motor Mount Gasket; Fits Suburban Furnace NT-40 | |
77 | NTP#Â 94-1719 | STAG#Â 73-0985 | CST# | MFR#Â 390179 | APPLIANCE COMPONENTS RV; Suburban Comb Air Housing | |
78 | NTP#Â 73-0025 | STAG#Â 73-0025 | CST# | MFR#Â 121436 | APPLIANCE COMPONENTS RV; Screw #10-16 X 1/2 | |
79 | NTP#Â 46-7245 | STAG#Â 46-7245 | CST# | MFR#Â 350069 | APPLIANCE COMPONENTS RV; Wheel Blower Small 6-1/4 | |
80 | NTP#Â 73-0025 | STAG#Â 73-0025 | CST# | MFR#Â 121436 | APPLIANCE COMPONENTS RV; Screw #10-16 X 1/2 | |
81 | NTP#Â 41-1032 | STAG#Â 79-8543 | CST#Â 61295 | MFR#Â 70386 | Furnace Gasket; Furnace Combustion Air Housing Gasket; Fits Suburban Furnace NT-24/ NT-30/ NT-34H/ NT-HA/ NT-34S/ NT-30SP/ NT-34HS/ NT-30MA/ NT-34L/ NT-34MM/ P-30S/ P-40S/ NT-42S/ NT-42ST | |
82 | NTP#Â 98-5882 | STAG#Â 73-0524 | CST# | MFR#Â 390424 | Furnace Combustion Air Housing Cover; For Suburban Furnace NT30SP/ NT34SP/ NT40 | |
82 | NTP# | STAG# | CST# | MFR#Â 390240 | HOUSING,AIR USE 390424 | |
83 | NTP#Â 69-9845 | STAG#Â 73-0021 | CST# | MFR#Â 121252 | Screw; For Suburban Furnace NT-Series; Fits Suburban Furnace Combustion Chamber; #10 x 3/8 Inch | |
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
Item:
NTP:
Stag:
Coast:
MFR:
Part Description:
Part Notes:
NT34LR -- REPLACEMENT
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
---|---|---|---|---|---|---|
1 | NTP#Â 08-0354 | STAG#Â 79-1822 | CST#Â 60185 | MFR#Â NT34SPN | Furnace Core; NT Series; LP Gas; Model Number NT-34SP; 34,000 BTU; Direct Discharge; 7.5 Amp Draw; 12 Inch Width x 12-1/2 Inch Height x 23 Inch Depth; 10.3 Pounds; With Energy-Saving Electronic Ignition; With Gasket-Sealed Vent Assembly | Wall thermostat removed from the furnace package beginning August 1, 2012. If the thermostat is needed, please order separately as p#161154 (79-8622).... |
Item | NTP | Stag | Coast | MFR | Part Description | Part Notes |
Item:
NTP:
Stag:
Coast:
MFR:
Part Description:
Part Notes: